Knight
Hawk Supply
Your One-Stop Hydraulic Source
Commercial Intertech Series 300 and 400 Pumps and Motors -- Repair Parts,
Hydraulic Pumps, Motors, and Valves
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Commercial
Intertech
(Commercial Shearing)
Phase II Bushing Pump
Series 300 and 400 Pumps and Motors |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dimensional Data Single
Pumps & Motors |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
Tandem Pumps & Motors |
|
|
|
 |
|
|
|
|
*
This dimension will vary with type of drive shaft. ** This dimension will vary
with type of ports. T=Total.
Weights
The following are the approximate weights of a single 1” gear section in each
frame size:
P315 ........ 18 lbs.
P330......... 36 lbs.
P350 ........ 51 lbs.
P365......... 56 lbs.
For each additional 1/4” of gear width add:
P315 ............ 1 lb.
P330..... 1 1/4 lbs.
P350 .... 1 1/2 lbs.
P365..... 2 1/2 lbs.
To find the approximate weight of a multiple section assembly, add the weight
of each section as a single. For the 330 frame size subtract 10% from this figure. |
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
315 Pump Performance
Data |
|
|
| Performance
data shown are the average results based on a series of laboratory tests of
production units and are not necessarily representative of any one unit. Tests
were run with the oil reservoir temperature at 120°F and viscosity 150 SUS
at 100°F. Note: Pump output flow is at the maximum rated pressure |
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
315 Motor Performance
Data |
|
|
|
 |
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
330 Pump Performance Data |
|
|
| Performance
data shown are the average results based on a series of laboratory tests of
production units and are not necessarily representative of any one unit. Tests
were run with the oil reservoir temperature at 120°F and viscosity 150 SUS
at 100°F. Note: Pump output flow is at the maximum rated pressure. |
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
330 Motor Performance
Data |
|
|
|
 |
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
350 Pump Performance Data |
|
|
| Performance
data shown are the average results based on a series of laboratory tests of
production units and are not necessarily representative of any one unit. Tests
were run with the oil reservoir temperature at 120°F and viscosity 150 SUS
at 100°F. Note: Pump output flow is at the maximum rated pressure. |
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
350 Motor Performance
Data |
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
365 Pump Performance Data |
|
|
| Performance
data shown are the average results based on a series of laboratory tests of
production units and are not necessarily representative of any one unit. Tests
were run with the oil reservoir temperature at 120°F and viscosity 150 SUS
at 100°F. Note: Pump output flow is at the maximum rated pressure |
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
365 Motor Performance
Data |
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
|
|
|
|
|
400 Series Pumps |
|
|
Commercials P400 series of high pressure, fixed displacement gear pumps
are available in single and multiple assemblies. These units are rated for
service up to 4500 psi. Theyre available in three models offering you
a displacement range from 1.5 to 5.5 CIR. These units are cast from high-strength
iron which provides the structural integrity needed at high pressures. Gear
widths have been selected to keep shaft deflections and bearing loads within
acceptable design limits. Body seals have been strengthened and the fastener
pre-load increased to assure reliability under high pressure conditions. A
wide variety of SAE B and C mounting flanges and drive shaft configurations
are available. Porting is through SAE split flange or O ring fitting.
Special hardened steel alloy gears with integral drive shaft run between pressure-balanced,
bronze wear plates to make these rugged pumps highly efficient. Long shaft
journals provide superior bearing surfaces and add to long service life. Pumps
can be assembled for rotation in either direction.
Displacement per inch of gear
P430 1.97 CIR
P450 2.55 CIR
P465 3.60 CIR
Oil Recommendations
Commercial pumps work well on most good hydraulic oil as well as synthetic
and fire resistant fluids. Some of these products require special seals.
Viscosity 50 SUS min. @ operating temperature.
7500 SUS max. @ starting temperature
Viscosity index 90 minimum
Analine point 175 minimum
Additives Foam depressant
Rust inhibitors
Maximum recommended system operating temperature
is 180° F. or 83° C.
Dimensional Data

315 Series - Special Assemblies
P315/M315 gears with various
drive shafts.
P315 port end cover with
built-in relief valve. Tandem use only - no inlet port available.
P315 port end cover with
side ports up to 1 I/2" S.F. inlet.
P315 port end cover with
integral priority valve. Built-in relief valve on primary circuit.
Clutch pump mount model
available.
330 Series - Special Assemblies
P330 dual outlet pump bearing
carrier that will accept a 2 1/2" S.F. inlet port.
P330/M330 gears with optional
number of gear teeth (10 tooth gears are standard; 13 tooth gears are optional).
P330/M330 gears with various
drive shafts and gear widths.
P330/315 piggyback.
P330 port end cover with
side ports up to 2" S.F. inlet.
Narrow P330 dual rotation
port end cover that accepts side and/or rear ports.
Narrow P330 port end cover
that accepts side and/or rear ports.
P330 port end cover that
accepts rear threaded ports.
P330 port end cover with
integral priority valve. No relief valve on primary circuit.
P330 pad mount shaft end
cover with two drive shafts.
P330 SAE "B" 2
bolt short shaft end cover.
FD330 flow divider assemblies.
350 Series - Special Assemblies
P350/M350 gears with optional
number of gear teeth (10 tooth gears are standard; 13 tooth gears are optional).
P350/M350 gears with various
drive shafts and gear widths.
P350/315 piggyback.
P350 add-a-pump port end
cover with the ability to mount any pump that has an SAE "A" or
"B" 2 bolt mounting flange and SAE "A" or "B"
splined drive shaft.
P350 port end cover that
is shorter and narrower than standard P350 PEC. Accepts 1 1/2"
diameter beaded inlet tube.
P350/M350 SAE "C"
4 bolt, ductile iron shaft end cover.
P350/M350 SAE "B"
2 bolt short shaft end cover.
FD350 flow divider assemblies.
365 Series - Special Assemblies
P365 bearing carriers with
special porting arrangments accept 3" S.F. inlet ports.
P365/M365 gears with various
drive shafts and gear widths.
P365/330 piggyback.
P365 add-a-pump port end
cover with the ability to mount any pump that has an SAE "A" or
"B" 2 bolt mounting flange and SAE "A" or "B"
splined drive shaft.
M365 SAE "C" 4
bolt, compacted graphite shaft end cover.
FD365 flow divider assemblies.
Call,
Fax or Email Knight Hawk Supply for more information on
Commercial Intertech parts and components

|
|
|
|
Knight
Hawk Supply
89 Zips Road
Hawk Point, MO 63349
(636) 338-4031 Fax (636) 338-4434
Toll Free (877) 739-3200
© 2004-2005 Copyright Knight Hawk Supply, Inc.